Industrial-data-systems IDS Scale Basic Manuale Utente Pagina 43

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 53
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 42
Scale Basic 4.2E Reference
Example Purpose1:
trigger user function 1 when gross weight is greater than Memory register 12 (weight above
setpoint).
Upper register Memory12
Lower register Gross
Execute Function User1
trigger user function 2 when Memory register 12 is greater than Gross weight (weight below
setpoint).
Upper register Gross
Lower register Memory12
Execute Function User2
Example Purpose2:
trigger user function 6 when scale is stable (motion false)
Upper register False
Lower register Motion
Execute Function User6
trigger user function 9 when TTL input 3 is high (true, inactive)
Upper register True
Lower register Input3
Execute Function User9
Vedere la pagina 42