6.0 INTERFACE PORTS / WIRING LISTS
The DT210 has 3 interface ports:
1. SERIAL CHANNEL 1: RS232 or CURRENT LOOP
The input of Channel 1 is normally used for interfacing to a weigh meter. The
output of Channel 1 is used for connecting to a printer.
2. SERIAL CHANNEL 2: RS232, CURRENT LOOP, or RS485.
Channel 2 is used for interfacing to a second weigh meter, a second printer, or a
computer.
3. PARALLEL TTL: 9 TTL outputs, 2 TTL inputs
Used for optional Centronix compatible printer output and control functions
(bulk-weigh, red light/green light, etc.)